Viscometers Support
  • Download
  • Archive

SEKONIC Support Contact by Mail

In-line viscometer(For embedded applications) FVM70A/72A Siries


Embedded applications inline viscometer FVM70A-ST
Catalog

Compact inline viscometer can also be used in the lab Catalog

FVM70A-ST

Summary

FVM70A is a torsional oscillation viscometer of inline process applications.
It measures the viscosity and temperature in real time and continuously attached to tank,and pipe with the flange.
Maintenance-free viscometer due to piezoelectric ceramic in the driving unit.
Viscosity sensor portion (probe) has become a full sealed structure, non-explosion proof type is also possible to soak in the liquid the entire probe addition to being attached at the flange.
It is possible to viscosity measured in flow state of liquid by attaching to the pipe that the flow of the liquid and the tank is agitated.

Feature

FVM70A-ST


High precision is achieved by downsizing the technology of FVM80A series
Adopts DC24V to be abele to share the same supply as the control equipment
By adopting the same probe and FVM80A / FEM-1000V, standardization of piping design is feasible.


FVM72A


High precision is achieved by downsizing the technology of FVM80A series
It uses an AC adapter, making it easier to use as a lab machine.
Downsized in combination with the VM-200T2, T3 probe.

System configuration FVM70A-ST

System configuretion FVM70A-ST

Specifications

TYPE FVM70A-ST
Measuring Range L-Type *Note 1 M-Type *Note 1 H-Type *Note 1
0.5~1000mPa・s 10~5000mPa・s 500~20000mPa・s
Accuracy ±2%(Reading) *Note 2
Repeatability ±1%(Reading) *Note 2
Temperature Range 0~100℃
Wetted temperature range 0~70℃
Calibrating method Calibration with Standard Liquids for Calibrating Viscometers(JIS Z8809-2011)
Viscosity display 3-digit LCD display (Without decimal point)
Temperature display 3-digit LCD display (Without decimal point)
System requirements 10~40°C, 20~80%RH(No condensation)
Analog output 4~20mA viscosity ×1 temperature × 1
Digital output RS232C interface output
Power Input:DC24V 700mA
Probe mounting size Insertion hole diameter:Φ46、Mounting bolt:Φ60 on the circumference, M4 × 4 pieces
Wetted Materials Flange: SUS304, the vibrator part: SUS316
Weight and Dimensions Probe:Φ46・Φ70×L190[mm](including a connecting portion), approximately 1.4kg
Controller: H72xW220xD220[mm] (except the connecting portion and terminal block) approximately 1.7kg
Accessories Connecting cable (5m) *Note 3, manual
*Note1 Select range L, M, H range of measurement.
*Note2 Measurement condition:At the room temperature using a JISZ8809 viscosity calibration standard liquids, measured with stirring at a liquid temperature of 23 ± 3 ℃ by stirrer or etc.
*Note3 Maximum 10m, up to 20m can be extended (paid option)

*Option (paid)


Teflon coated probe
(Probe: FVM80A-PST-T02)
2S ferrule installation
(Probe: FVM80A-PST-F01)


TYPE FVM72A-VM-200T2 FVM72A-VM-200T3
Measuring Range L-Type
*Note 1
M-Type
*Note 1
H-Type
*Note 1
L-Type
*Note 1
M-Type
*Note 1
H-Type
*Note 1
0.5~
1000mPa・s
10~
5000mPa・s
500~
20000mPa・s
0.5~
1000mPa・s
10~
5000mPa・s
500~
20000mPa・s
Accuracy ±2%(Reading) *Note 2
Repeatability ±1%(Reading) *Note 2
Temperature Range 0~100℃
Wetted temperature range 0~70℃
Calibrating method Calibration with Standard Liquids for Calibrating Viscometers (JIS Z8809-2011)
Viscosity display 3-digit LCD display  (Without decimal point)
Temperature display 3-digit LCD display  (Without decimal point)
System requirements 10~40°C, 20~80%RH (No condensation)
Analog output 0~5V viscosity × 1   temperature × 1
Digital output RS232C interface output
Power AC adapter (Input: AC100~240V, Output: DC9V 2,600mA)
Probe mounting size Insertion hole diameter:Φ35(T3,T2), Mounting bolt:Φ50(T3) on the circumference, M4×4 pieces(T3)
Wetted Materials Flange: SUS304, the vibrator part: SUS316
Weight and Dimensions Probe:Φ34 (T2) ・ Φ70 (T3 flange) xL220 (including a connecting portion) approximately 0.75kg
Controller: H72xW220xD220[mm] (except the connecting portion and terminal block) approximately 1.7kg
Accessories Connecting cable (5m) *Note 3, manual
Option Temperature sensor (Pt)
*Note1 Select range L, M, H range of measurement.
*Note2 Measurement condition:At the room temperature using a JISZ8809 viscosity calibration standard liquids, measured with stirring at a liquid temperature of 23 ± 3 ℃ by stirrer or etc.
*Note3 Maximum 10m, up to 20m can be extended (paid option)


Probe VM-200T2
Probe VM-200T3